Transmitter M300 FLOW 21
© 09 / 08 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter M300 FLOW
Printed in Switzerland 52 121 319
4.4 Connection of Sensor
The M300 FLOW Transmitter is designed to operate with various types of sensors. These
sensors require different wiring configurations. Listed below are instructions for wiring the
various types of sensors offered by Mettler-Toledo Thornton for use with this transmitter. Please
consult the factory for assistance if attempting to wire sensors not offered by Mettler-Toledo
Thornton as some sensors may not be compatible.
4.5 Flow Sensor Input Wiring Kit
This kit contains components that may be needed at input terminals to condition sensor signals.
Refer to the following sections or to the instruction manual for wiring details.
4.6 Kit Contents
This kit contains the following items:
4x Wire nuts
4x 10K ohm resistors for use with Burket 8020 and 8030 type sensors, and GF Signet
2500-series sensors.
4x 1K ohm resistors for use with Data Industrial 200-series and Fluidyne insertion type
sensors.
4x 0.33uF, 50 V capacitors for use with Berket 8020 and 8030 type sensors, Data
Industrial 200-series and 4000-series sensors, GF Signet 2500-series sensors, Sanitary
Turbine-Type sensors, Fluidyne insertion type sensors and Racine Federated (Formerly Asahi/
America) vortex-style sensors.
4.7 Flow sensor wiring for Compatible Sensors
The following sections provide wiring information to properly connect various compatible flow
sensors to the M300 FLOW Transmitter. When using the Configuration menu of the transmitter to
setup the flow sensor, the first prompt asks to select the TYPE of flow sensor being connected.
There are three choices as follows:
High: All flow sensors described in Section 4.5.1
Low: P515 Signet flow sensors only, described in section 4.5.2
Type 2: Asahi flow sensors, described in Section 4.5.3